Before installation
Daylight and any existing lighting at canopy height, as the starting point for the design.
Light Science
Every figure on this site is labelled by where it comes from. Three checks stand behind them: the light calculation against an independent simulation, the sun data against a second satellite record, and the light measured in the greenhouse before and after installation.
01 · Calculation check
The engine behind the light maps, DLI and energy figures on this site was run in six reference rooms and compared with an open-source horticultural lighting simulator built on Radiance. Mean PPFD agrees within 3% in every room. Point by point the two differ by 7–13%, and for LED the engine shows the light as more even than Radiance does.
SimulationA comparison of two simulations, not a measurement.
Loading the light map…
Step 1/4
Room, fixture positions, light output and dimming are the same in both. The two differ in how light leaves a fixture and how the walls return it.
Step 2/4
PPFD on the calculation plane from this site’s engine. Brighter means more light.
Step 3/4
The room mean is what DLI, lit hours and energy are built on. With wall reflectance 0.9 the engine lies between −2.7% and +1.5% of Radiance in all six rooms.
Step 4/4
Under the fixtures the engine computes less light than Radiance; between fixtures and along the walls, more. For LED this makes min/avg look better: 0.33–0.46 in the engine against 0.26–0.35 in Radiance.
Reference room
Wall reflectance in the engine
The simulator’s walls and ceiling reflect 0.9; that is the main comparison.
| Room | Radiance mean | Engine mean | Difference | Point RMSE | Largest point | Min/avg Radiance | Min/avg engine |
|---|---|---|---|---|---|---|---|
| LED 10 × 10 ft | 250 | 250 | −0.1% | 8.6% | 18% | 0.33 | 0.40 |
| LED 30 × 15 ft | 250 | 245 | −1.9% | 8.2% | 18% | 0.26 | 0.33 |
| LED 50 × 30 ft | 250 | 243 | −2.7% | 7.0% | 15% | 0.35 | 0.46 |
| HPS 10 × 10 ft | 727 | 738 | +1.5% | 12.7% | 34% | 0.20 | 0.21 |
| HPS 30 × 15 ft | 877 | 875 | −0.3% | 11.8% | 30% | 0.13 | 0.14 |
| HPS 50 × 30 ft | 1,063 | 1,052 | −1.0% | 10.9% | 25% | 0.16 | 0.17 |
02 · Sun data check
Daylight figures for Türkiye start from NASA POWER satellite data. They were checked against a second, independent satellite record, PVGIS, in all 81 provinces.
SimulationThis check covers outdoor solar radiation; it does not test the light that passes through a greenhouse cover. Sunshine hours were checked against measurements: monthly error 0.76 h/day.
Step 1/2
Each dot is a province: the difference in annual solar radiation. Median +1.0%; 80% of provinces lie between −2.7% and +6.7%. Over 972 monthly values the correlation is 0.992.
Step 2/2
Along the eastern Black Sea coast NASA is well above PVGIS: Giresun +22%, Rize +17%, Trabzon +14%, Ordu +12%. NASA’s grid of about 1° cannot separate the narrow coastal strip from the cloud over the mountains behind it.
Data: NASA POWER, PVGIS · CC BY 4.0 · Processed by WONE.
03 · On site
A calculation is checked against the crop. In the greenhouse or a test room, light is recorded where the crop grows, before and after installation, and handed over in a form that can be repeated next season.
Daylight, logged separately
Two lines in the report
Survey report
| # | Measured | Calculated |
|---|---|---|
| 1 | ||
| 2 | ||
| 3 |
Flag: zone below its design value
Calculated map, greenhouse model · Simulation
Step 1/4
PPFD is read on a fixed grid across the crop area. Every position is recorded, so the survey can be repeated at the same points next season.
Step 2/4
The lamp contribution is measured with daylight excluded, after dark or with blackout screens closed. Natural light is logged on its own.
Step 3/4
One spectral reading per luminaire type. PAR (400–700 nm) and far-red (700–800 nm) are reported on separate lines and never added together.
Step 4/4
Instrument, calibration date, conditions and positions on every page, and each reading beside the calculated value for the same point. A zone below its design value is flagged.
Daylight and any existing lighting at canopy height, as the starting point for the design.
The same grid, set against the calculated map, with the spectrum per luminaire type and the settings as handed over.
Flicker: the temporal light modulation of the luminaires is measured at every dimming level and given on a separate line of the report. For WONE luminaires in development, this measurement is a mandatory part of the design. Concept
Uniformity
Three numbers, over the crop area only: minimum to average, average to maximum and the coefficient of variation. Paths and edges appear on the map and stay out of the statistics.
Evidence labels
Four labels keep measured values apart from calculated, published and proposed ones.
Recorded with a calibrated instrument at a stated position and time. Instrument and calibration date are reported with the value.
On this page: none.
Calculated from stated geometry, data and assumptions. The interactive models on this site carry this label.
On this page: the engine maps, the room comparison and the satellite radiation records.
Taken from published research or recognised grower guidance. Cultivar, climate and crop stage move these ranges.
Elsewhere on the site: crop targets for DLI, photoperiod and PPFD.
An approach or product in development, shown to explain the idea. No performance figure is attached to it.
On this page: flicker measurement.
Data and controls
The calculation that sizes an installation also sets its lit hours and dimming through the year, and the measured light is kept beside it.
Light-distribution calculation, DLI and energy schedules, and interactive models like the ones on this site.
Canopy readings logged against the calculated map, with a flag when a zone falls below its design value.
Crop, location, structure and what is already installed are enough to begin. We reply with the questions that shape the lighting design and an outline of what we would calculate and measure.