01 · Blue · 450 nm
Blue is absorbed
Chlorophyll absorbs blue strongly. The leaf reflects only 7% of it.
Light Science
Three properties of light decide what it does for a crop: its colour, its daily total and how evenly it falls across the plants.
01 · Colour
Blue and red light are absorbed by the leaf and drive photosynthesis. Green is partly reflected, which is why leaves look green, and most of it is still absorbed. Far-red adds little to photosynthesis on its own and acts mainly through phytochrome, the pigment that senses the balance of red and far-red.
Animation
The colour channels of a luminaire switch on in turn. The leaf reflects each colour at the rate published for lettuce leaves; the other photons enter the leaf. With red and far-red, the gauge shows how much phytochrome is in its active form, Pfr.
Reduced motion: still image. Choose a colour to see its step.
01 · Blue · 450 nm
Chlorophyll absorbs blue strongly. The leaf reflects only 7% of it.
02 · Green · 550 nm
The leaf reflects 19% of green light, which is why it looks green. Most of the rest is still absorbed and drives photosynthesis.
03 · Red · 660 nm
The leaf reflects 6% of red. Red light also turns phytochrome from Pr into its active form, Pfr: under red alone the Pfr share reaches 0.87.
04 · Far-red · 730 nm
Chlorophyll absorbs little far-red: the leaf reflects 42% and lets most of the rest through. Phytochrome absorbs it and turns Pfr back into Pr: with the red + far-red linear the Pfr share falls to 0.73.
Reflected by the leaf
Lettuce leaf, share of photons reflected
Phytochrome
Responds to red and far-red
Spectrum lab
Pick a light and a second one to compare. The chart shows each spectrum by wavelength; the cards show what the plant and the eye make of it. Every value is calculated from the spectrum.
Loading the spectra…
Move along the chart to read the values at each wavelength.
Blue · green · red
Light: 0% · 0% · 100%
Compare with: 30% · 36% · 34%
Share of PAR photons in 400–500, 500–600 and 600–700 nm
ePAR / PAR
Light: 1.60
Compare with: 1.16 · 14.0%
Far-red, 700–750 nm, is 37.4% of ePAR. Reported separately, never added to PAR.
Phytochrome, PSS
Light: 0.73
Compare with: 0.68
Pfr / Ptotal. More far-red lowers it, as shade does.
R:FR
Light: 2.24
Compare with: 1.05
Photons at 655–665 nm over 725–735 nm
YPF / PPF, approximate
Light: 1.04
Compare with: 0.88
Photons weighted by McCree’s curve, per PAR photon. Can exceed 1, because 700–725 nm counts.
To the eye
Light: Not white light
Compare with: 6,503 K · Ra 100
Too red to count as white
Lumens per µmol PAR
Light: 8lm per µmol/s
Compare with: 56 lm per µmol/s
A lux reading divided by this estimates PPFD in µmol/m²/s.
A lettuce leaf on a white card
Colours calculated from the leaf’s reflectance and the spectrum. The eye adapts to a white light; a camera set for daylight does not.
WONE photoperiod linear, red + far-red
Not white light: the eye cannot adapt fully, so the camera view is the closer guide.
Daylight, CIE D65
Curves are relative, peak = 1; the ratios do not depend on intensity. The luminaire classes are modelled, not measured, and the WONE photoperiod linear is a development target.
| Light | Blue / green / red, % of PAR | ePAR / PAR | Far-red, % of ePAR | R:FR | PSS | YPF / PPF, approx. | To the eye | lm per µmol/s |
|---|---|---|---|---|---|---|---|---|
| WONE photoperiod linear, red + far-redDevelopment target · modelled, not measured | 0 / 0 / 100 | 1.60 | 37.4 | 2.2 | 0.73 | 1.04 | Not white | 8 |
| Toplight, red + blueSimulation · modelled, not measured | 15 / 0 / 85 | 1.02 | 2.3 | 48 | 0.85 | 0.95 | Not white | 8 |
| Toplight, broad white + redSimulation · modelled, not measured | 16 / 20 / 64 | 1.05 | 4.5 | 17 | 0.83 | 0.91 | Not white | 37 |
| Interlight, red + blueSimulation · modelled, not measured | 14 / 0 / 86 | 1.00 | 0.0 | – | 0.86 | 0.95 | Not white | 8 |
| Rack LED barSimulation · modelled, not measured | 21 / 25 / 54 | 1.02 | 2.2 | 44 | 0.84 | 0.89 | Not white | 43 |
| Home LED barSimulation · modelled, not measured | 21 / 28 / 51 | 1.03 | 2.5 | 33 | 0.83 | 0.89 | Not white | 48 |
| Night-break lampSimulation · modelled, not measured | 2 / 30 / 69 | 1.02 | 1.5 | 99 | 0.85 | 0.93 | 2,286 K · Ra 82 | 52 |
| HPS 1000 W, genericLiterature · generic spectrum, digitised | 5 / 51 / 44 | 1.05 | 4.7 | 2.7 | 0.81 | 0.91 | 2,048 K · Ra 25 | 81 |
| Horticultural LED, genericLiterature · generic spectrum, digitised | 18 / 44 / 39 | 1.01 | 0.9 | 37 | 0.84 | 0.86 | 3,844 K · Ra 87 | 69 |
| White LED 3000 KLiterature · generic spectrum, digitised | 12 / 45 / 43 | 1.02 | 2.3 | 9.4 | 0.83 | 0.87 | 3,084 K · Ra 81 | 72 |
| White LED 5000 KLiterature · generic spectrum, digitised | 22 / 48 / 29 | 1.02 | 1.5 | 9.5 | 0.81 | 0.83 | 4,946 K · Ra 81 | 73 |
| Daylight, CIE D65CIE standard illuminant | 30 / 36 / 34 | 1.16 | 14.0 | 1.1 | 0.68 | 0.88 | 6,503 K · Ra 100 | 56 |
02 · Daily light
PPFD is the light arriving on each square metre every second. The daily light integral (DLI) adds it up over the hours the light is on: DLI = PPFD × hours × 0.0036.
Animation
A light sensor at the top of a lettuce crop reads PPFD while the lamp is on; the day’s total collects as the hours pass.
Reduced motion: the whole day is shown at once.
PPFD
0µmol/m²/s
PAR sensor · Time of day 00:00
243 µmol/m²/s × 16 h × 0.0036 = 14.0 mol/m²/day
Light so far today
0.0mol/m²
Lettuce target 12–17
Calculator
Set the PPFD at the crop and the hours of light. The result is compared with published targets for the crop you choose.
Daily light integral
14.4mol/m²/day
Literature
mol/m²/day
Published range; cultivar, season and growth stage move it.
24-hour schedule
Photoperiodic crops such as strawberry and dragon fruit respond to the length of the night. A night break of 4 h at 1.6 µmol/m²/s (dragon fruit) or 2 µmol/m²/s (strawberry) in the middle of the night splits a long night in two; its light adds only 0.03 mol/m²/day.
From a lux reading to PPFD
ApproximateA lux meter weighs light by the sensitivity of the human eye, so its reading converts to PPFD only for a known light source.
Approximate PPFDµmol/m²/s
From the lumens per µmol of each spectrum in the spectrum lab. Under red and blue light a lux meter reads low: there 1 µmol/m²/s is only about 8 lux, against 56 lux in daylight.
In a greenhouse, daylight adds to the lamp: the targets are daily totals from both.
Units
Plants respond to photons, so light on this site is always given as a photon quantity, in the waveband it names.
Photons a luminaire emits in the PAR band each second.
Photons arriving on each square metre of canopy each second.
The day’s total on each square metre, from lamps and daylight together.
PAR photons delivered for each joule of electrical input.
Reported on its own line and never added to PAR.
Input power, and the energy a lighting schedule uses over a day or a season.
Extended PAR (400–750 nm) is a research convention and appears only where it is stated. UV-A and UV-B are reported separately.
Illuminance (lux) is weighted to human vision. We quote it only when comparing with older studies that used it, and in the lux converter above.
03 · Uniformity
Under and between the luminaires the light at the crop rises and falls. Uniformity, the lowest value divided by the average (min/avg), shows how deep the dips are; the coefficient of variation (CV) shows how much the whole field varies.
Animation
The luminaire rows above a crop move apart and back. The light map at the crop and its uniformity are calculated for each step.
PPFD across the rows
Reduced motion: two row spacings side by side.
Against a reference simulation of LED rooms with reflective walls, the engine gave a min/avg of 0.33–0.46 and the reference 0.26–0.35, so uniformity here can look better than it is. Measurement and validation
Calculator
Change the layout and the site’s engine recalculates the map.
Row spacing / height1.6
Calculated area 12 × 9.6 m in the middle of a large compartment; luminaire: toplight class, red + blue, 330 W, modelled.
PPFD across the rows
Against a reference simulation of LED rooms with reflective walls, the engine gave a min/avg of 0.33–0.46 and the reference 0.26–0.35, so uniformity here can look better than it is. Measurement and validation
Crop, location, structure and what is already installed are enough to begin. We reply with the questions that shape the lighting design and an outline of what we would calculate and measure.