1. WONE Lighting
  2. Horticultural Lighting
  3. Light Science
  4. Light and plants

Light Science

The effects of light on plants

Three properties of light decide what it does for a crop: its colour, its daily total and how evenly it falls across the plants.

  1. 01Which colour does what?
  2. 02How much light in a day?
  3. 03Does it fall evenly?

01 · Colour

Which colour does what in a plant?

Blue and red light are absorbed by the leaf and drive photosynthesis. Green is partly reflected, which is why leaves look green, and most of it is still absorbed. Far-red adds little to photosynthesis on its own and acts mainly through phytochrome, the pigment that senses the balance of red and far-red.

Animation

Light reaching a lettuce leaf

The colour channels of a luminaire switch on in turn. The leaf reflects each colour at the rate published for lettuce leaves; the other photons enter the leaf. With red and far-red, the gauge shows how much phytochrome is in its active form, Pfr.

Light on a leaf

Reduced motion: still image. Choose a colour to see its step.

01 · Blue · 450 nm

Blue is absorbed

Chlorophyll absorbs blue strongly. The leaf reflects only 7% of it.

02 · Green · 550 nm

Green is partly reflected

The leaf reflects 19% of green light, which is why it looks green. Most of the rest is still absorbed and drives photosynthesis.

03 · Red · 660 nm

Red is absorbed and switches phytochrome on

The leaf reflects 6% of red. Red light also turns phytochrome from Pr into its active form, Pfr: under red alone the Pfr share reaches 0.87.

04 · Far-red · 730 nm

Far-red turns phytochrome back

Chlorophyll absorbs little far-red: the leaf reflects 42% and lets most of the rest through. Phytochrome absorbs it and turns Pfr back into Pr: with the red + far-red linear the Pfr share falls to 0.73.

Reflected by the leaf

  • Blue 450 nm7%
  • Green 550 nm19%
  • Red 660 nm6%
  • Far-red 730 nm42%

Lettuce leaf, share of photons reflected

Phytochrome

Pfr share, PSS
  • Red 660 nm alone: 0.87
  • Red + far-red: WONE photoperiod linear, development target: 0.73
  • Daylight, CIE D65: 0.68

Responds to red and far-red

Literature: reflected shares of a lettuce leaf. Pfr shares for 660 nm alone and for the modelled spectrum of the WONE photoperiod linear (development target). The number and speed of the photons are illustrative.

Spectrum lab

Compare two lights

Pick a light and a second one to compare. The chart shows each spectrum by wavelength; the cards show what the plant and the eye make of it. Every value is calculated from the spectrum.

Spectrum labSimulation
On the chart

Move along the chart to read the values at each wavelength.

Blue · green · red

Light: 0% · 0% · 100%

Compare with: 30% · 36% · 34%

Share of PAR photons in 400–500, 500–600 and 600–700 nm

ePAR / PAR

Light: 1.60

Compare with: 1.16 · 14.0%

Far-red, 700–750 nm, is 37.4% of ePAR. Reported separately, never added to PAR.

Phytochrome, PSS

Light: 0.73

Compare with: 0.68

Pfr / Ptotal. More far-red lowers it, as shade does.

R:FR

Light: 2.24

Compare with: 1.05

Photons at 655–665 nm over 725–735 nm

YPF / PPF, approximate

Light: 1.04

Compare with: 0.88

Photons weighted by McCree’s curve, per PAR photon. Can exceed 1, because 700–725 nm counts.

To the eye

Light: Not white light

Compare with: 6,503 K · Ra 100

Too red to count as white

Lumens per µmol PAR

Light: 8lm per µmol/s

Compare with: 56 lm per µmol/s

A lux reading divided by this estimates PPFD in µmol/m²/s.

A lettuce leaf on a white card

Colours calculated from the leaf’s reflectance and the spectrum. The eye adapts to a white light; a camera set for daylight does not.

WONE photoperiod linear, red + far-red

Camera, daylight setting

Not white light: the eye cannot adapt fully, so the camera view is the closer guide.

Daylight, CIE D65

Eye
Camera, daylight setting

Curves are relative, peak = 1; the ratios do not depend on intensity. The luminaire classes are modelled, not measured, and the WONE photoperiod linear is a development target.

All lights in one table
LightBlue / green / red, % of PARePAR / PARFar-red, % of ePARR:FRPSSYPF / PPF, approx.To the eyelm per µmol/s
WONE photoperiod linear, red + far-redDevelopment target · modelled, not measured0 / 0 / 1001.6037.42.20.731.04Not white8
Toplight, red + blueSimulation · modelled, not measured15 / 0 / 851.022.3480.850.95Not white8
Toplight, broad white + redSimulation · modelled, not measured16 / 20 / 641.054.5170.830.91Not white37
Interlight, red + blueSimulation · modelled, not measured14 / 0 / 861.000.0–0.860.95Not white8
Rack LED barSimulation · modelled, not measured21 / 25 / 541.022.2440.840.89Not white43
Home LED barSimulation · modelled, not measured21 / 28 / 511.032.5330.830.89Not white48
Night-break lampSimulation · modelled, not measured2 / 30 / 691.021.5990.850.932,286 K · Ra 8252
HPS 1000 W, genericLiterature · generic spectrum, digitised5 / 51 / 441.054.72.70.810.912,048 K · Ra 2581
Horticultural LED, genericLiterature · generic spectrum, digitised18 / 44 / 391.010.9370.840.863,844 K · Ra 8769
White LED 3000 KLiterature · generic spectrum, digitised12 / 45 / 431.022.39.40.830.873,084 K · Ra 8172
White LED 5000 KLiterature · generic spectrum, digitised22 / 48 / 291.021.59.50.810.834,946 K · Ra 8173
Daylight, CIE D65CIE standard illuminant30 / 36 / 341.1614.01.10.680.886,503 K · Ra 10056

02 · Daily light

How much light does my plant get in a day?

PPFD is the light arriving on each square metre every second. The daily light integral (DLI) adds it up over the hours the light is on: DLI = PPFD × hours × 0.0036.

Animation

A day at the measuring point

A light sensor at the top of a lettuce crop reads PPFD while the lamp is on; the day’s total collects as the hours pass.

A day at the measuring point

Reduced motion: the whole day is shown at once.

PPFD

0µmol/m²/s

PAR sensor · Time of day 00:00

243 µmol/m²/s × 16 h × 0.0036 = 14.0 mol/m²/day

Light so far today

0.0mol/m²

Lettuce target 12–17

Example: lettuce with a 16-hour photoperiod, at the PPFD that gives the target of 14.0 mol/m²/day in 16 hours. Target range 12–17 mol/m²/day from published research. Daylight is not included.

Calculator

Daily light, targets and day length

Set the PPFD at the crop and the hours of light. The result is compared with published targets for the crop you choose.

Daily light calculatorLiterature
µmol/m²/s

Daily light integral

14.4mol/m²/day

Literature

mol/m²/day

Published range; cultivar, season and growth stage move it.

Typical PPFD
Typical day length

24-hour schedule

Photoperiodic crops such as strawberry and dragon fruit respond to the length of the night. A night break of 4 h at 1.6 µmol/m²/s (dragon fruit) or 2 µmol/m²/s (strawberry) in the middle of the night splits a long night in two; its light adds only 0.03 mol/m²/day.

From a lux reading to PPFD

Approximate

A lux meter weighs light by the sensitivity of the human eye, so its reading converts to PPFD only for a known light source.

Approximate PPFDµmol/m²/s

From the lumens per µmol of each spectrum in the spectrum lab. Under red and blue light a lux meter reads low: there 1 µmol/m²/s is only about 8 lux, against 56 lux in daylight.

In a greenhouse, daylight adds to the lamp: the targets are daily totals from both.

Units

The units we design and report in

Plants respond to photons, so light on this site is always given as a photon quantity, in the waveband it names.

PPFµmol/s

Photosynthetic photon flux

Photons a luminaire emits in the PAR band each second.

Band 400–700 nm
PPFDµmol/m²/s

Photosynthetic photon flux density

Photons arriving on each square metre of canopy each second.

Band 400–700 nm
DLImol/m²/day

Daily light integral

The day’s total on each square metre, from lamps and daylight together.

Band 400–700 nm
µmol/Jµmol/J

Photon efficacy

PAR photons delivered for each joule of electrical input.

Band 400–700 nm
FRµmol/s · µmol/m²/s

Far-red

Reported on its own line and never added to PAR.

Band 700–800 nm
kWhW · kWh

Power and energy

Input power, and the energy a lighting schedule uses over a day or a season.

Extended PAR (400–750 nm) is a research convention and appears only where it is stated. UV-A and UV-B are reported separately.

Illuminance (lux) is weighted to human vision. We quote it only when comparing with older studies that used it, and in the lux converter above.

03 · Uniformity

Does light fall evenly everywhere?

Under and between the luminaires the light at the crop rises and falls. Uniformity, the lowest value divided by the average (min/avg), shows how deep the dips are; the coefficient of variation (CV) shows how much the whole field varies.

Animation

Rows of luminaires moving apart

The luminaire rows above a crop move apart and back. The light map at the crop and its uniformity are calculated for each step.

Light map at the cropSimulation
Row spacing, m

Reduced motion: two row spacings side by side.

Rows 1.6 m apartMin / avg 0.93 · Average PPFD 342 µmol/m²/s · CV 0.02
Rows 4.8 m apartMin / avg 0.63 · Average PPFD 116 µmol/m²/s · CV 0.25
Simulation: toplight class, red + blue (modelled, 330 W), 8 per 12 m row, 2.0 m above the crop, in the middle of a large compartment.

Against a reference simulation of LED rooms with reflective walls, the engine gave a min/avg of 0.33–0.46 and the reference 0.26–0.35, so uniformity here can look better than it is. Measurement and validation

Calculator

Spacing, height and number of luminaires

Change the layout and the site’s engine recalculates the map.

Uniformity calculatorSimulation

Row spacing / height1.6

Calculated area 12 × 9.6 m in the middle of a large compartment; luminaire: toplight class, red + blue, 330 W, modelled.

12 m9.6 mCalculating…
Min / avg0.84
CV0.09
Average PPFD166µmol/m²/s
Lowest140µmol/m²/s
Highest192µmol/m²/s

PPFD across the rows

Against a reference simulation of LED rooms with reflective walls, the engine gave a min/avg of 0.33–0.46 and the reference 0.26–0.35, so uniformity here can look better than it is. Measurement and validation

Discuss your project

Crop, location, structure and what is already installed are enough to begin. We reply with the questions that shape the lighting design and an outline of what we would calculate and measure.