1. Home
  2. Light Science
  3. Measurement and validation

Light Science

Why should I trust these figures?

Every figure on this site is labelled by where it comes from. Three checks stand behind them: the light calculation against an independent simulation, the sun data against a second satellite record and ground stations, and the light measured in the greenhouse before and after installation.

01 · Calculation check

How accurate is our calculation?

The engine behind the light maps, DLI and energy figures on this site was run in six reference rooms and compared with an open-source horticultural lighting simulator built on Radiance. Mean PPFD agrees within 3% in every room. Point by point the two differ by 7–13%, and for LED the engine shows the light as more even than Radiance does.

SimulationA comparison of two simulations, not a measurement.

Engine and Radiance · six reference roomsSimulation

Loading the light map…

LED 30 × 15 ft · 9.1 × 4.6 mρ 0.9
245µmol/m²/s
Engine mean
Radiance mean 250Difference −1.9%
Under fixtures: engine lowerWalls and gaps: engine higher

Step 1/4

One room, two calculations

Room, fixture positions, light output and dimming are the same in both. The two differ in how light leaves a fixture and how the walls return it.

AspectRadiance simulatorSite engine
Light leaving a fixtureMeasured distribution (IES file)Symmetric cosᵐ curve with the same half-angle
Walls and ceilingDiffuse, reflectance 0.9; floor 0.1Mirror image of each fixture in each wall, 0.9
Reflections followedThree bouncesOne

Same in both: room, fixture positions, PPF and dimming.

Step 2/4

The engine’s light map

PPFD on the calculation plane from this site’s engine. Brighter means more light.

Room
LED 30 × 15 ft · 9.1 × 4.6 m
Fixtures
18 × 8-bar LED, 1,716 µmol/s
Lamp height above the plane
0.46 m
Output
dimmed to 34%
Engine mean
245 µmol/m²/s
Radiance mean
250 µmol/m²/s
Min/avg, engine · Radiance
0.33 · 0.26
CV, engine · Radiance
23.4% · 29.9%

Step 3/4

Mean PPFD within 3%

The room mean is what DLI, lit hours and energy are built on. With wall reflectance 0.9 the engine lies between −2.7% and +1.5% of Radiance in all six rooms.

±3%−15%−10%−5%0+5%Difference from RadianceRadianceEngineLED 10 × 10 ft−0.1%LED 30 × 15 ft−1.9%LED 50 × 30 ft−2.7%HPS 10 × 10 ft+1.5%HPS 30 × 15 ft−0.3%HPS 50 × 30 ft−1.0%

Step 4/4

Single points differ by 7–13%

Under the fixtures the engine computes less light than Radiance; between fixtures and along the walls, more. For LED this makes min/avg look better: 0.33–0.46 in the engine against 0.26–0.35 in Radiance.

0.00.10.20.30.40.5Minimum / averagePoint RMSERadianceEngineLED 10 × 10 ft8.6%LED 30 × 15 ft8.2%LED 50 × 30 ft7.0%HPS 10 × 10 ft12.7%HPS 30 × 15 ft11.8%HPS 50 × 30 ft10.9%
Point RMSE
8.2%
Largest point difference
18%

Reference room

Wall reflectance in the engine

The simulator’s walls and ceiling reflect 0.9; that is the main comparison.

Animated comparison in four steps: the reference room, the light map from the site engine, the room means against Radiance, and the differences point by point.
All six rooms, all numbers
Engine against Radiance, wall reflectance 0.9 in the engine. PPFD in µmol/m²/s.
RoomRadiance meanEngine meanDifferencePoint RMSELargest pointMin/avg RadianceMin/avg engine
LED 10 × 10 ft250250−0.1%8.6%18%0.330.40
LED 30 × 15 ft250245−1.9%8.2%18%0.260.33
LED 50 × 30 ft250243−2.7%7.0%15%0.350.46
HPS 10 × 10 ft727738+1.5%12.7%34%0.200.21
HPS 30 × 15 ft877875−0.3%11.8%30%0.130.14
HPS 50 × 30 ft1,0631,052−1.0%10.9%25%0.160.17

Method and sources

Reference rooms
Three sizes: 10 × 10, 30 × 15 and 50 × 30 ft (3.0 × 3.0 to 15.2 × 9.1 m). LED: 8-bar fixtures of 660 W, dimmed so that Radiance gives a room mean of 250 µmol/m²/s. HPS: 1000 W lamps at full output. Lamps 0.46 m (LED) and 0.61 m (HPS) above the calculation plane.
Engine set-up
Each LED bar is a 1.19 m line source carrying an eighth of the fixture’s PPF, half-angle 60°. Each HPS lamp is a line source along its 0.80 m opening, half-angle 48°. Half-angles are averages from the fixtures’ IES files. Maintenance factor 1, as in the simulator.
Why they differ
The engine gives every fixture a rotationally symmetric distribution and reflects light once off each wall, as a mirror image. Radiance follows the measured distribution and diffuse reflections from walls, ceiling and floor over three bounces. With wall reflectance 0 the engine falls up to 13% below Radiance, in the smallest LED room.
Limits
Both sides of this comparison are simulations, and the simulator has not been checked against measurements either. For a project, measured fixture data (IES, LM-79) and a canopy survey remain the reference.
What it means on this site
Mean PPFD, DLI, lit hours and energy rest on the room mean. Uniformity from the engine is optimistic for LED layouts: read min/avg as an upper estimate.
Automated test
The six rooms are recalculated as an automated test before each release. The engine’s mean PPFD must stay within ±5% of Radiance.
Source
Open-source horticultural lighting simulator built on Radiance (Lawrence Berkeley National Laboratory), BSD-3-Clause-Clear licence, version dfe2f84. The Radiance results are those supplied with the simulator.

02 · Sun data check

Why can the sun data be trusted?

Daylight figures for Türkiye start from NASA POWER satellite data. They were checked against a second, independent satellite record, PVGIS SARAH-3, in all 81 provinces, and against sunshine hours measured at MGM ground stations in 76.

SimulationThese checks cover outdoor solar radiation and sunshine. They do not test the light that passes through a greenhouse cover.

NASA POWER against PVGIS and MGM · TürkiyeSimulation
80% of provincesmedian +1.0%−10%−5%0+5%+10%+15%+20%+25%Annual solar radiation, NASA against PVGISAfter correction: monthly means equal PVGIS
−0.50+0.5+1.0+1.5+2.0+2.5Mean difference from MGM, h/dayWMO threshold+2.2 h/dayRMSE 2.32 · r 0.955FAO-56, standard coefficients+1.0 h/dayRMSE 1.28 · r 0.967Calibrated to MGM, tested on unseen regions−0.04 h/dayRMSE 0.76 · r 0.964
0.00.40.81.2Test error (RMSE) by region, h/daySoutheastern Anatolia0.51Eastern Anatolia0.64Central Anatolia0.66Black Sea0.78Marmara0.80Aegean0.81Mediterranean1.10

Step 1/5

NASA against PVGIS in 81 provinces

Each dot is a province: the difference in annual solar radiation. Median +1.0%; 80% of provinces lie between −2.7% and +6.7%. Over 972 province-months the correlation is 0.992.

Correlation, NASA and PVGIS
0.992
Mean difference, NASA − PVGIS
+0.27 MJ/m²/day
Median province, annual
+1.0%

Step 2/5

Where NASA reads high

Along the eastern Black Sea coast NASA is well above PVGIS: Giresun +22%, Rize +17%, Trabzon +14%, Ordu +12%. NASA’s grid of about 1° cannot separate the narrow coastal strip from the cloud over the mountains behind it.

Step 3/5

Monthly means set to PVGIS

For every province and month the mean radiation is set equal to PVGIS. NASA’s day-to-day variation is kept, so dark and bright days stay in the record.

Step 4/5

Sunshine hours against MGM

Sunshine duration is estimated from radiation. With standard coefficients the estimate is too high: +2.2 h/day with the WMO threshold, +1.0 h/day with FAO-56. Calibrated to MGM, the mean difference is −0.04 h/day.

Mean difference after calibration
−0.04 h/day
Correlation with MGM
0.964

Step 5/5

Tested on regions left out

The coefficients were fitted on six regions and tested on the seventh, each region in turn. Test error 0.76 h/day over 76 provinces; by region from 0.51 to 1.10 h/day.

Test error after calibration
0.76 h/day
Correlation with MGM
0.964
Animated check in five steps: annual solar radiation from NASA against PVGIS for each province, the coastal outliers, the monthly correction, sunshine hours against MGM ground stations, and the test on regions left out of the calibration.

Sun and daylight: the figures by province and month

Method and sources

Satellite radiation
NASA POWER Hourly API v2.10.5, 2016–2025, local solar time (CC BY 4.0).
Second satellite record
PVGIS v5.3, SARAH-3, 2016–2023, European Commission Joint Research Centre; horizon shading off.
Ground stations
MGM province statistics: long-term monthly mean sunshine duration. Used only for calibration and validation.
Sunshine from radiation
Ångström–Prescott relation (FAO-56), coefficients calibrated to MGM: a = 0.256, b = 0.565. Annual mean per province after calibration: median absolute difference 0.24 h/day, 90th percentile 0.64 h/day.
Quality control
Left out: Bayburt and Bitlis (no record), İstanbul and Giresun (annual mean of 1.9 h/day, not physically plausible), and Muğla (the station listed for the province reports coastal values, while the province centre lies at 666 m).
Limits
Values hold for the province centre point; in provinces that run from the coast to the mountains, places within the province differ widely. They are ten-year averages, and the weather on a given day can differ from them. Sunshine duration is estimated and was checked against MGM ground-station records.

03 · On site

What does WONE measure and deliver?

A calculation is checked against the crop. In the greenhouse or a test room, light is recorded where the crop grows, before and after installation, and handed over in a form that can be repeated next season.

Canopy survey · methodConcept
Lamps only

Daylight, logged separately

Two lines in the report

400500600700800
  • PAR 400–700 nmµmol/m²/s
  • Far-red 700–800 nmµmol/m²/s

Survey report

Instrument
Calibration date
Conditions
Positions
#MeasuredCalculated
1
2
3

Flag: zone below its design value

Calculated map, greenhouse model · Simulation

Step 1/4

Points at canopy height

PPFD is read on a fixed grid across the crop area. Every position is recorded, so the survey can be repeated at the same points next season.

Step 2/4

Lamps and daylight apart

The lamp contribution is measured with daylight excluded, after dark or with blackout screens closed. Natural light is logged on its own.

Step 3/4

Spectrum per luminaire type

One spectral reading per luminaire type. PAR (400–700 nm) and far-red (700–800 nm) are reported on separate lines and never added together.

Step 4/4

A report that can be checked

Instrument, calibration date, conditions and positions on every page, and each reading beside the calculated value for the same point. A zone below its design value is flagged.

  • Crop area
  • Path
  • Survey point
Animated method in four steps: survey points at canopy height across the crop area, lamps and daylight measured apart, the spectrum with PAR and far-red on separate lines, and the survey report.

Before installation

Daylight and any existing lighting at canopy height, as the starting point for the design.

After installation

The same grid, set against the calculated map, with the spectrum per luminaire type and the settings as handed over.

Standards we refer to

Quantities and units follow ANSI/ASABE S640. Luminaire data refer to ANSI/ASABE S642, IES LM-79 and the IES TM-33 data format.

  1. ANSI/ASABE S640 JUL2017 (R2022). Quantities and Units of Electromagnetic Radiation for Plants (Photosynthetic Organisms). ASABE. webstore.ansi.org
  2. ANSI/ASABE S642 SEP2018. Recommended Methods for Measurement and Testing of LED Products for Plant Growth and Development. ASABE. webstore.ansi.org
  3. ANSI/ASABE S642.1 SEP2025. Measurement and testing of electromagnetic radiation sources (LED and non-LED) for plant growth, 280-800 nm. ASABE. webstore.ansi.org
  4. ANSI/IES LM-79-24. Optical and Electrical Measurements of Solid-State Lighting Products. IES, 2024.
  5. ANSI/IES TM-33-23. Standard Format for the Electronic Transfer of Luminaire Optical Data. IES, 2023. shop.standards.ie
  6. DesignLights Consortium. Horticultural Lighting Technical Requirements V4.0 (effective 18 April 2025). designlights.org
  7. DesignLights Consortium (2021). Horticultural Lighting Resources: Terms and Definitions. designlights.org
  8. DesignLights Consortium (2021). Limitations of Predicting Far-Red's Effect on Photosynthesis (white paper). designlights.org
Greenhouse model · TomatoSimulation
  • Crop area
  • Paths, not counted
Mean PPFD
199 µmol/m²/s
Min/avg
0.89
Avg/max
0.92
CV
5.9%

Uniformity

How uniformity is reported

Three numbers, over the crop area only: minimum to average, average to maximum and the coefficient of variation. Paths and edges appear on the map and stay out of the statistics.

Min/avg
Lowest point divided by the mean. 1 would be perfectly even.
Avg/max
Mean divided by the highest point.
CV
Standard deviation divided by the mean.

In the six reference rooms the engine gave a higher min/avg than Radiance for LED: 0.33–0.46 against 0.26–0.35. Read uniformity from the engine as an upper estimate.

Evidence labels

Where each figure comes from

Four labels keep measured values apart from calculated, published and proposed ones.

Measured

Recorded with a calibrated instrument at a stated position and time. Instrument and calibration date are reported with the value.

On this page: none. Ground-station sunshine records were used only to calibrate and check the estimates.

Simulation

Calculated from stated geometry, data and assumptions. The interactive models on this site carry this label.

On this page: the engine maps, the room comparison and the satellite radiation records.

Literature

Taken from published research or recognised grower guidance, with the source listed. Cultivar, climate and crop stage move these ranges.

Elsewhere on the site: crop targets for DLI, photoperiod and PPFD.

Concept

An approach or product in development, shown to explain the idea. No performance figure is attached to it.

On this page: the canopy survey drawing.

Data and controls

From a light plan to a daily schedule

The calculation that sizes an installation also sets its lit hours and dimming through the year, and the measured light is kept beside it.

Service

Available now

Light-distribution calculation, DLI and energy schedules, and interactive models like the ones on this site.

Concept

Measured light beside the plan

Canopy readings logged against the calculated map, with a flag when a zone falls below its design value.

Discuss your project

Crop, location, structure and what is already installed are enough to begin. We reply with the questions that shape the lighting design and an outline of what we would calculate and measure.